Uninterrupted off-grid portable emergency backup power station modular UPS

No break Off-grid Portable Emergency backup Power station Modular UPSMain Features· Double conversion topology technology, pure sine wave output.· Advanced DSP digital control technology.· Environmental Friendly and energy saving, as the input power factor is up to 0.99.· Wide input voltage

Featured Products

No break Off-grid Portable Emergency backup Power station Modular UPS

Main Features
· Double conversion topology technology, pure sine wave output.
· Advanced DSP digital control technology.
· Environmental Friendly and energy saving, as the input power factor is up to 0.99.
· Wide input voltage and frequency range, 110 VAC --240 VAC, 40 -- 70 Hz.
· 0ms Line-Bat transfer , ensure the safety and reliablity of load. 
· ECO mode optional, reduce the  UPS power consumption. 
· Low audible noise (below 50 dB), will not affect your daily life. 
No Break off-Grid Portable Emergency Backup Power Station Modular UPS

Specfictations
Model1K2K3K6K10K
PhaseSingle phase with ground
Input
Rate capacity1KVA/800W2KVA/1.6KW3KVA/2.4KW6KVA/4.8KW10KVA/8KW
Rate voltage110/115/120/127VAC or 220/230/240VAC220/230/240VAC
Turn on voltage range 55-150VAC or 110-300VAC  50% load110-300VAC  50% load
85-140VAC or 160-280VAC  100% load176-300VAC  100% load
Frequency range40~70Hz46~54Hz or 56~64Hz
Power factor0.99  100% load
OUTPUT
Rate voltage110/115/120/127VAC or 220/230/240VAC220/230/240VAC
Voltage regulation±1%
Line mode frequency47~53Hz or 57~63Hz46~54Hz or 56~64Hz
Bat mode frequency50Hz or 60Hz
Voltage harmonic3%   R load3%   R load
6%   RCD load5%   RCD load
Crest ration3:01
Line-Bat transfer0ms
INV-Bypass transfer4ms0ms
Over load105%±5%<load≤125%±5%:1min;125%±5%< load ≤150%±5%:30s;load>150%±5%:300ms;   (transfer to bypass and alarm)
Efficiency
Line mode> 88%> 88%> 90%> 92%> 93%
Bat mode> 83%> 85%> 88%> 90%> 91%
Bat
Number24616 or 20
Charger voltage27.4VDC54.7VDC82.1VDC218.4VDC/273VDC
Charge current (stand)1A1A/2A
Charge current(long)1A/2A/4A/6A(adjustable,20 Bat can't select 6A)
Size(length*width*height)and weight
Stand UPS(mm)318*438*88410*438*88630*438*88//
Weight(kg)9.81727.6//
Long time UPS(mm)318*438*88410*438*88510*438*88580*438*133
Weight(kg)91214.21518
Environment
Work temperature0ºC~40ºC
Work humidity20%~95%
Audible noise50dB55dB58dB
CommunicationRS-232/USB/SNMP card  adjustable